PPR Pipes & Fittings
DIN 8077/8078 PPR in PN16, PN20 and PN25 for cold and hot water, with matching fittings.
Source PPR, PEX, copper and stainless pipes, fittings, valves, water heaters and pumps from verified Chinese makers — with hydrostatic pressure tests, wall-thickness checks, WRAS / NSF / SASO compliance and project loading handled end to end.
Plumbing is hidden in walls and shafts. A weak fitting or under-spec pipe doesn't show up at delivery — it shows up at the system pressure test, after the wall is closed. Most failures are predictable and avoidable before shipment.
PPR pipes labelled PN20 with actual wall thickness closer to PN16, failing pressure tests.
Fittings that look identical to brand product but fail under fusion welding on site.
Ball and gate valves leaking under pressure because seat material was downgraded.
Products specified for drinking water with no valid potable-water certification.
Different production batches with different markings shipped together, confusing site QA.
Booster pumps sized on a catalogue page instead of on the project's actual head and flow.
From plumbing BOQ to riser-packed cartons, every step is handled by a sourcing team that reads MEP drawings and understands what an installer needs to commission the system on time.
We map pipes, fittings, valves and equipment per riser and floor with required pressure rating.
We compare pipe, valve and equipment makers by certifications and pressure-test track record.
Sample pipes and fittings pressure-tested; valves seat-tested; pumps duty-point verified.
Pre-shipment QC, per-riser packing, certificate pack and supervised container loading.
DIN 8077/8078 PPR in PN16, PN20 and PN25 for cold and hot water, with matching fittings.
PEX-A and PE-RT pipes for underfloor heating and modular bathroom run-outs.
EN 1057 copper and 304/316 stainless press-fit systems for premium projects.
CPVC for hot water and fire-fighting branches with NSF and FM options.
Soil and waste stacks, rainwater downpipes and underground HDPE drainage systems.
PE foam and elastomeric foam pipe insulation, plus PVC service jackets for plant rooms.
Brass and stainless ball valves, gate and check valves in DN15 to DN300.
Pressure-reducing valves and balancing valves for high-rise plumbing risers.
Storage and instant electric heaters 30–500 L with safety thermostats and TPR valves.
Low-NOx gas heaters and R32 heat-pump water heaters for high-volume domestic hot water.
Single and multi-stage booster pumps, VFD pump sets and diaphragm pressure tanks.
Fire pumps with UL/FM options, jockey pumps, sprinkler valves and hose reel cabinets.
Plumbing scopes live or die on what's locked before the PO — wall thickness, PN rating, valve seat material, pump duty. We commit each in writing against your riser drawing.
You can also explore our complete project quote workflow or learn more about JEES Global.
Send BOQ & Riser DiagramPipes ship from Hangzhou, valves from Wenzhou, heaters from Foshan, pumps from Shanghai. We make those four supply chains behave like one — matched specs, one packing list, one container plan.
What blows out the system test on site is almost always something a careful inspector would have caught two weeks earlier at the factory. We catch it there, photograph it, and only then release cartons.
Real inspection and loading photos are shared with every shipment. Placeholders shown for illustration.
A plumbing order is long, heavy and easy to muddle in transit. We bundle by riser, label by floor and load with paperwork that matches — so the install crew opens crates, not investigations.
Pipes bundled with end caps and labels per riser, fittings and valves in cartons by SKU.
Test reports, WRAS / NSF / SASO certificates, packing list per riser and certificate of origin.
FOB, CIF or CFR with weight-balanced loading and supervised container sealing.
How the same component catalogue gets reshaped per asset class — what a 30-storey residential tower needs is not what a boutique hotel or villa cluster needs.
PPR risers, copper hot-water loops, hotel-grade valves and heat-pump water heaters.
Per-unit metering, booster pump sets, drainage stacks and unit-pack PEX bathroom kits.
Stainless press-fit risers, balancing valves and high-capacity booster systems.
Copper or stainless service lines, gas water heaters and outdoor irrigation valves.
Grease-trap-compatible drainage, instant water heaters and food-grade stainless lines.
Fire pumps, jockey pumps, sprinkler valves and hose reel cabinets with code-compliant listings.
Plumbing is hidden the moment walls close — buyers tell us they want a partner who treats every batch like it's about to be sealed behind plaster, because it is.
Talk to our sourcing teamHydrostatic tests, valve seat checks, pump curves and riser-pack imagery — packaged in a single proof file your consulting engineer can review before the container ever leaves Yantian.
Pipe and fitting samples with batch markings and PN rating reference.
Hydrostatic pressure test photos and signed reports per pipe batch.
Seat tightness, torque and dimensional checks recorded per valve type.
Pumps tested against project duty point with motor name-plate verified.
Bundles labelled per riser and floor for fast site issue.
Weight-balanced loading sequence and final container photos.
WRAS, NSF, SASO, KIWA and ISO documents collected per shipment.
Pre-shipment QC report with photos, measurements and tests per batch.
We don't publish fake badges or stock photos. Real proof — sample, inspection, packaging and loading photos — is shared per order to your team and procurement records.
Even a partial BOQ or a riser sketch is enough to begin. We turn it into a shortlist, sample plan and line-item quotation you can put in front of the project engineer.
Send Plumbing BOQSpecs, material grades, surface treatments & project checklist
PDF · Free · Instant deliveryShare the BOQ, riser diagram and any equipment schedule you have. We come back with shortlisted factories, sample plans and a clean per-riser quotation.
Prefer to talk first? Visit our contact page or browse how JEES Global works.